Skip to main content

Official Journal of the Japan Wood Research Society

  • Original Article
  • Published:

Pseudodynamic tests and earthquake response analysis of timber structures III: three-dimensional conventional wooden structures with plywood-sheathed shear walls

Abstract

Pseudodynamic (PSD) tests were conducted on plywood-sheathed conventional Japanese three-dimensional (3D) wooden structures. Lateral load was applied to the edge beam of specimen structures to generate eccentricity loading. Specimens were based on a combination of shear walls with openings in the loading direction and horizontal diaphragms with different shear stiffness. The principle deformation of the horizontal diaphragm was torsion for rigid diaphragms and shear deformation for flexible diaphragms. Lumped-mass time-history earthquake response analysis was conducted on the tested structures, and additional calculations were conducted on structures with different eccentricity rates. Dynamic analyses were conducted by varying the masses and the resistance of the walls in the loading direction. The simulated peak displacement response in the loading plane agreed comparatively well with the PSD test results. The maximum displacement response on changing the wall resistant ratio showed almost the same tendency as that obtained by changing the mass ratio up to an eccentricity rate of 0.3; however, the maximum displacement response increased markedly beyond an eccentricity rate of 0.4. It was proved that the lumped-mass 3D model proposed in this study was appropriate for conducting a parameter study on the 3D dynamic behavior of timber structures.

References

  1. Shing PB, Nakashima M, Bursi OS (1996) Application of pseudodynamic test method to structural research. Earthq Spectra 12:29–56

    Article  Google Scholar 

  2. Kamiya F, Sugimoto K, Mii N (1996) Pseudo dynamic test of sheathed wood walls. In: Proceedings of the 1996 IWEC, vol 2. Omnipress, Madison, pp 187–194

    Google Scholar 

  3. Kawai N (1998) Pseudo-dynamic test on shear walls. In: Proceedings of the 5th WCTE, vol 1, August, 1998, EPF Lausanne, Montreux, Switzerland, pp 412–419

  4. Yasumura M (2001) Evaluation of damping capacity of timber structures for seismic design. In: Proceedings of the 34th CIB-W18, Venice, Italy, paper 34-15-3, pp 1–9

  5. Yasumura M, Yasui S (2006) Pseudodynamic tests and earthquake response analysis of timber structures I: plywood-sheathed conventional wooden walls with opening. J Wood Sci 52:63–68

    Article  Google Scholar 

  6. Yasumura M, Kamada T, Iimura Y, Uesugi M, Daudeville L (2006) Pseudodynamic tests and earthquake response analysis of timber structures II: two-level conventional wooden structures with plywood sheathed shear walls. J Wood Sci 52:69–74

    Article  Google Scholar 

  7. Japan Housing and Wood Technology Center (2003) The testing method of metal fastenings and fasteners for wooden construction (in Japanese). Japan Housing and Wood Technology Center, Tokyo

    Google Scholar 

  8. Japan Agricultural Standard (2008) JAS for plywood (in Japanese). JAS, Tokyo

    Google Scholar 

  9. ISO (2010) ISO 21581-2010: timber structures — static and cyclic lateral load test method for shear walls. ISO, Geneva

    Google Scholar 

  10. Japan Housing and Wood Technology Center (2001) Allowable strength design for Japanese conventional construction (in Japanese). Japan Housing and Wood Technology Center, Tokyo

    Google Scholar 

  11. Richard N, Yasumura M, Davenne L (2003) Prediction of seismic behavior of wood-framed shear walls with openings by pseudodynamic test and FE model. J Wood Sci 49:145–151

    Article  Google Scholar 

  12. Yasumura M, Uesugi M, Luc D (2006) Estimating 3D behaviour of conventional timber structures with shear walls by pseudo-dynamic test. In: Proceedings of the 37th CIB-W18, August 30–Septmeber 3, Edinburgh, Scotland

  13. Richard N, Yasumura M (2008) Dynamic model for 3D timber structures with plywood sheathed shear walls. In: Proceedings of the 10th WCTE, June 2–5, Miyazaki, Japan

  14. Yasumura M, Nicolas R, Luc D, Uesugi M (2006) Estimating seismic performance of timber structures with plywood-sheathed walls by pseudo-dynamic tests and time-history earthquake response analysis. In: Proceedings of the 9th WCTE, August 6–10, Portland, OR, USA

  15. Yasumura M (2003) Pseudo-dynamic tests on conventional timber structures with shear walls. In: Proceedings of the 36th CIB-W18, August 11–14, Colorado, USA

  16. Foschi RO (1974) Load-slip characteristics of nails. Wood Sci 7(1):69–76

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takahisa Kamada.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kamada, T., Yasumura, M., Yasui, S. et al. Pseudodynamic tests and earthquake response analysis of timber structures III: three-dimensional conventional wooden structures with plywood-sheathed shear walls. J Wood Sci 57, 484–492 (2011). https://doi.org/10.1007/s10086-011-1198-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10086-011-1198-6

Key words