Official Journal of the Japan Wood Research Society
From: Prediction of compressive strength of cross-laminated timber panel
Statistics | |
---|---|
Repetition | 39 |
Average compressive strength (MPa) | 47.93 |
Standard deviation (MPa) | 5.34 |
Coefficient of variation (%) | 11.14 |
Minimum compressive strength (MPa) | 37.19 |
Maximum compressive strength (MPa) | 59.96 |
5th percentile strength (MPa) | 38.36 |
Weibull distribution parameter | |
Scale (η) | 50.03 |
Shape (β) | 11.18 |