Skip to main content

Official Journal of the Japan Wood Research Society

Table 5 Summary of the torque test results

From: Torque loading tests on the rolling shear strength of cross-laminated timber

CLT type

Peak failure torque load (N × mm)

Weibull fitting parameters

No. of specimen with rolling shear failure

Calculated shear strength (N/mm2)

Mean

Standard deviation

Coefficient of variation (%)

Location

Scale

Shape

Mean

SPF5-0.4

103,989

17,058

16.40

0.00

110,378.29

7.42

31

3.79

SPF3-0.4

84,561

14,048

16.61

0.00

89,210.22

7.86

25

3.36