From: Torque loading tests on the rolling shear strength of cross-laminated timber
CLT type | Peak failure torque load (N × mm) | Weibull fitting parameters | No. of specimen with rolling shear failure | Calculated shear strength (N/mm2) | ||||
---|---|---|---|---|---|---|---|---|
Mean | Standard deviation | Coefficient of variation (%) | Location | Scale | Shape | Mean | ||
SPF5-0.4 | 103,989 | 17,058 | 16.40 | 0.00 | 110,378.29 | 7.42 | 31 | 3.79 |
SPF3-0.4 | 84,561 | 14,048 | 16.61 | 0.00 | 89,210.22 | 7.86 | 25 | 3.36 |