Table 3 Summary of the calculated \( T_{\text{V}} \) values (in \( {\text{kN}}/{\text{MPa}} \)) for cross laminated timber (CLT)

From: Reliability analysis and duration-of-load strength adjustment factor of the rolling shear strength of cross laminated timber

 

\( T_{\text{V}} \) from layered beam theory

\( T_{\text{V}} \) from gamma beam theory

\( T_{\text{V}} \) from shear analogy theory

Five-layer CLT

11.24

11.90

11.76

Three-layer CLT

7.46

10.20

7.46