Skip to main content

Official Journal of the Japan Wood Research Society

Table 8 The errors between 95% reliability pullout resistance and calculated value by Sine function

From: Influence of welded depth and CuCl2 pretreated dowels on wood dowel welding

Group

95% reliability pullout resistance (N)

Calculated value (N)

Error (%)

A-10

482

472

2.07

A-20

631

669

6.02

A-30

1385

1334

3.68

A-40

1690

1733

2.54

A-50

1446

1429

1.18

  1. Group A-10 meant the untreated group, and the number 10 meant the welded depth 10 mm