Official Journal of the Japan Wood Research Society
From: Acoustic emission signal source localization on plywood surface with cross-correlation method
Acoustic emission (AE) source | Actual coordinates (Xi, 0) | The time difference of AE signal, µs | Coordinates after calculating (X′i, 0) | Absolute error (X″i, 0) | Relative error, % |
---|---|---|---|---|---|
C | −15 | 63.453 | −14.958 | 0.042 | 0.280 |
 | −15 | 62.643 | −14.767 | 0.233 | 1.553 |
 | −15 | 62.834 | −14.812 | 0.188 | 1.253 |
 | −15 | 63.525 | −14.975 | 0.025 | 0.167 |
 | −15 | 62.889 | −14.825 | 0.175 | 1.167 |
D | −5 | 21.155 | −4.987 | 0.013 | 0.260 |
 | −5 | 21.261 | −5.012 | 0.012 | 0.240 |
 | −5 | 22.072 | −5.203 | 0.203 | 4.060 |
 | −5 | 21.580 | −5.087 | 0.087 | 1.740 |
 | −5 | 21.732 | −5.123 | 0.123 | 2.460 |
O | 0 | 0.110 | 0.026 | 0.026 | – |
 | 0 | 0 | 0 | 0 | |
 | 0 | 0.687 | 0.162 | 0.162 | |
 | 0 | 0.106 | 0.025 | 0.025 | |
 | 0 | 0.369 | 0.087 | 0.087 | |
E | 5 | 21.609 | 5.094 | 0.094 | 1.880 |
 | 5 | 35.069 | 8.267 | 3.267 | 65.340 |
 | 5 | 21.011 | 4.953 | 0.047 | 0.940 |
 | 5 | 21.261 | 5.012 | 0.012 | 0.240 |
 | 5 | 21.346 | 5.032 | 0.032 | 0.640 |
F | 10 | 37.084 | 8.742 | 1.258 | 12.580 |
 | 10 | 42.234 | 9.956 | 0.044 | 0.440 |
 | 10 | 41.942 | 9.887 | 0.113 | 1.130 |
 | 10 | 42.145 | 9.935 | 0.065 | 0.650 |
 | 10 | 41.895 | 9.876 | 0.124 | 1.240 |
G | 17 | 72.268 | 17.036 | 0.036 | 0.211 |
 | 17 | 56.271 | 13.265 | 3.735 | 21.971 |
 | 17 | 73.622 | 17.355 | 0.355 | 2.088 |
 | 17 | 73.202 | 17.256 | 0.256 | 1.506 |
 | 17 | 74.826 | 17.639 | 0.639 | 3.759 |