Official Journal of the Japan Wood Research Society
From: Experimental study on the fire performance of straight-line dovetail joints
Specimen | Loading (kN) | Load level (%) | Protective coating | Fire resistance (min) | Converted fire resistance (min) |
---|---|---|---|---|---|
F25 | 5.1 | 25 | No | 47 | 46 |
F37.5 | 7.2 | 37.5 | No | 33 | 34 |
F50 | 10.3 | 50 | No | 29 | 28 |
FP50 | 10.3 | 50 | Yes | 38 | 38 |