Table 6 Summary of the fire resistance experimental results of straight-line dovetail joints

From: Experimental study on the fire performance of straight-line dovetail joints

Specimen

Loading (kN)

Load level (%)

Protective coating

Fire resistance (min)

Converted fire resistance (min)

F25

5.1

25

No

47

46

F37.5

7.2

37.5

No

33

34

F50

10.3

50

No

29

28

FP50

10.3

50

Yes

38

38