Official Journal of the Japan Wood Research Society
From: The evaluation of long-term mechanical properties of wood-based panels by indoor exposure tests
Panels | Mild humidity | Semi-mild humidity | High humidity | Cyclic humidity | Roof sheathing | Ceiling of eave | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6-y | 10-y | 5-y | 1/4-y | 1/2-y | 1-y | 2-y | 3-y | 5-y | 1/2-y | 1-y | 3/2-y | 2-y | 3-y | 5-y | 9.5-y | 9.5-y | |
Retention of bending strength, MOR (%) | |||||||||||||||||
OSB(A) | 87 | – | 71 a | 75 | 83 | 75 | 76 | 76 | 74 | 81 | 70 | 76 | 74 | 79 | 64 | 100 | 84 |
OSB(P) | 91 | – | 95 | 91 | 100 | 86 | 98 | 83 | 81 | 90 | 77 | 97 | 94 | 96 | 92 | 98 | 97 |
PB(P) | 96 | – | 96 | 83 | 100 | 100 | 87 | 72 | 67 | 90 | 85 | 98 | 86 | 88 | 75 | 100 | 100 |
PB(I) | 100 | – | 100 | 100 | 99 | 99 | 96 | 92 | 85 | 100 | 100 | 99 | 94 | 100 | 95 | 100 | 100 |
MDF(M) | 100 | – | 100 | 94 | 94 | 95 | 95 | 89 | 79 | 89 | 95 | 98 | 92 | 92 | 87 | 100 | 100 |
PW(P) | 75 | – | 75 | 80 | 78 | 79 | 88 | 75 | 80 | 65 | 68 | 100 | 80 | 80 | 88 | 100 | 100 |
Retention of modulus of elasticity, MOE (%) | |||||||||||||||||
OSB(A) | 83 | – | 69 | 79 | 83 | 64 | 75 | 62 | 62 | 76 | 67 | 77 | 69 | 63 | 56 | 96 | 77 |
OSB(P) | 85 | – | 91 | 86 | 94 | 79 | 88 | 76 | 73 | 88 | 78 | 93 | 84 | 84 | 74 | 100 | 99 |
PB(P) | 91 | – | 90 | 85 | 94 | 97 | 80 | 67 | 66 | 90 | 84 | 95 | 81 | 80 | 72 | 100 | 100 |
PB(I) | 100 | – | 94 | 100 | 98 | 96 | 92 | 84 | 75 | 100 | 96 | 100 | 89 | 87 | 90 | 100 | 98 |
MDF(M) | 100 | – | 99 | 95 | 94 | 93 | 96 | 85 | 75 | 92 | 92 | 96 | 91 | 85 | 84 | 100 | 100 |
PW(P) | 85 | – | 85 | 87 | 80 | 97 | 91 | 80 | 89 | 93 | 85 | 100 | 88 | 78 | 85 | 100 | 86 |
Retention of internal bond strength, IB (%) | |||||||||||||||||
OSB(A) | 61 | 71 | 64 | 68 | 66 | 65 | 70 | 67 | 69 | 62 | 56 | 63 | 55 | 75 | 33 | 86 | 76 |
OSB(P) | 83 | 90 | 92 | 88 | 94 | 82 | 93 | 68 | 82 | 100 | 80 | 77 | 75 | 86 | 72 | 88 | 89 |
PB(P) | 87 | 78 | 90 | 84 | 92 | 83 | 78 | 52 | 83 | 88 | 75 | 79 | 79 | 90 | 69 | 75 | 80 |
PB(I) | 89 | 86 | 93 | 100 | 95 | 90 | 89 | 85 | 85 | 100 | 100 | 99 | 89 | 93 | 87 | 84 | 88 |
MDF(M) | 100 | 100 | 100 | 100 | 100 | 77 | 100 | 100 | 97 | 100 | 100 | 100 | 95 | 100 | 100 | 88 | 100 |
PW(P) | 93 | 98 | 100 | 79 | 94 | 100 | 100 | 76 | 100 | 100 | 90 | 100 | 84 | 89 | 74 | 77 | 100 |
Retention of internal lateral nail resistance, LNR (%) | |||||||||||||||||
OSB(A) | 100 | 94 | 87 | 87 | 87 | 99 | 100 | 100 | 93 | 100 | 100 | 89 | 100 | 100 | 92 | 85 | 88 |
OSB(P) | 88 | 98 | 100 | 99 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 91 | 79 | 100 | 100 | 100 | 100 |
PB(P) | 94 | 88 | 100 | 100 | 100 | 99 | 96 | 100 | 100 | 100 | 100 | 98 | 100 | 100 | 99 | 76 | 99 |
PB(I) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 99 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
MDF(M) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 99 | 99 | 100 | 99 | 98 | 100 | 99 | 100 | 98 |
PW(P) | 100 | 100 | 100 | 99 | 100 | 100 | 100 | 100 | 98 | 98 | 90 | 97 | 100 | 100 | 100 | 95 | 94 |
Retention of nail-head pull-through resistance, NHPT (%) | |||||||||||||||||
OSB(A) | 99 | 97 | 100 | 75 | 77 | 100 | 100 | 89 | 100 | 90 | 81 | 95 | 94 | 96 | 93 | 80 | 81 |
OSB(P) | 100 | 95 | 95 | 94 | 97 | 100 | 86 | 95 | 100 | 100 | 100 | 100 | 96 | 100 | 100 | 74 | 88 |
PB(P) | 100 | 94 | 95 | 94 | 96 | 94 | 88 | 95 | 91 | 72 | 94 | 96 | 98 | 93 | 91 | 84 | 84 |
PB(I) | 100 | 95 | 100 | 90 | 96 | 99 | 93 | 98 | 92 | 72 | 93 | 96 | 91 | 100 | 96 | 83 | 86 |
MDF(M) | 98 | 100 | 99 | 96 | 95 | 99 | 100 | 95 | 99 | 77 | 99 | 99 | 99 | 100 | 99 | 76 | 90 |
PW(P) | 100 | 100 | 100 | 93 | 100 | 100 | 100 | 88 | 100 | 96 | 95 | 100 | 100 | 100 | 100 | 94 | 97 |