Skip to main content

Official Journal of the Japan Wood Research Society

Table 2 Fire-resistance test results

From: Relative improvements in flame resistance of coir fiberboards treated with fire-retardant solution

Sample

FR boron (wt%)

Flammability (min)

Flame penetration time (min)

Rate of burning (min)

Resistance to flame spread (min)

As per IS 1734: Part 3 (1983) [16]

As per IS 15491: 2004 [14]

FRCS 1

40

49.00

38.50

41.50

56.00

51.00

42.00

40.00

57.75

48.00

40.00

42.00

59.00

FRCS 2

35

55.00

38.00

42.25

65.00

56.00

35.50

44.00

62.00

50.00

39.25

46.50

59.00

FRCS 3

30

52.00

40.00

47.50

65.00

54.00

38.00

49.00

67.00

50.00

46.00

60.00

64.00

FRCS 4

25

44.00

35.00

44.50

62.00

43.50

35.50

51.00

64.00

40.00

39.00

46.50

57.00

FRCS 5

20

38.00

33.00

28.00

57.50

38.50

32.50

31.00

63.50

35.50

36.00

27.00

55.00

FRCS 6

15

30.25

30.00

26.00

57.00

26.50

30.00

26.15

55.00

29.00

29.50

27.25

60.00

FRCS 7

10

26.75

27.50

21.00

52.25

25.00

29.00

19.00

52.50

26.00

25.75

20.00

53.50

Untreated

0

34.00

25.00

12.00

6.00

32.50

27.00

13.00

6.00

35.50

29.50

11.00

6.00

  1. FRCS fire-retardant chemical solution, FR fire-retardant