Skip to main content

Official Journal of the Japan Wood Research Society

Table 2 Comparison of withdrawal and bending load capacities of experiment and FEM

From: A finite element model of semi-rigid mortise-and-tenon joint considering glue line and friction coefficient

Loading types

Experiment

COV

FEM

Ratio

Withdrawal (N)

5133

4.35

4998

0.97

Bending (N)

1130

8.24

960

0.85