Skip to main content

Official Journal of the Japan Wood Research Society

Table 2 Specification and load-carrying capacity of cross-laminated timber

From: Moment and shear capacity of Ply-lam composed with plywood and structural timber under out-of-plane bending

Test type

Dimensions (mm)

Failure mode

Thickness (thickness of lamina)

Width

Length

Test span

aa

Bending (%)

Rolling shear (%)

Shear test (\(R_{\text{sd}}\)b: 12/1)

123 (25/24/25/24/25)

300

1600

1476

615

52

48

Bending test (\(R_{\text{sd}}\): 25/1)

123 (25/24/25/24/25)

300

3200

3075

615

100

0

  1. aDistance between external support and load application point
  2. bSpan-to-depth ratio