Table 2 Mean and CV of the block shear tests

From: Effects of the presence or absence and the position of glued edge joints in the lamina on the shear strength of glued laminated timber

Group

Density

(kg/m3)

MC

(%)

Shear strength

(N/mm2)

Glued edge-joint (N = 34)

335 (7.15)

11.4 (3.27)

8.57 (15.7)

Solid wood (N = 34)

383 (9.49)

12.8 (5.28)

8.52 (10.1)

  1. The left and right values in the cell are the mean value and CV (in percentage)